CISCO Refurbished
- Manufacturer
- CISCO
- Condition
- Refurbished
- Lead Time
- 2-3 Days
- Availability
- Not In Stock
- List Price/RRP
- US$2,000.00
- Price
- US$786.00 Enquire
Description
The M-ASR1K-SSD-200GB is a product created by the renowned technology supplier, Cisco. It is essentially a Solid State Drive with a storage capacity of 200GB. This SSD is designed to work specifically with Cisco's ASR 1000 series routers, allowing for easy and efficient installation.As a Solid State Drive, the M-ASR1K-SSD-200GB offers faster read and write speeds compared to traditional hard drives. This makes it a reliable and efficient choice for businesses and organizations that require large amounts of data storage, such as data centers and telecom providers.The M-ASR1K-SSD-200GB offers secure data storage, ensuring the safety and protection of sensitive information. It is a reliable choice for businesses looking for speed, efficiency, and security in their data storage solutions. Cisco offers their customers a warranty with the purchase of the M-ASR1K-SSD-200GB, providing peace of mind and assurance of quality.- Part Code
- M-ASR1K-SSD-200GB
- Description
- Cisco ASR 1000 RP3 200 GB SSD
- Manufacturer
- CISCO
Route Processor Features, Benefits, Descriptions
Expand
Route Processor Features, Benefits, Descriptions
Support for Cisco IOS XE Software
Supports a breadth of IP network services, including quality of service (QoS), MPLS, Layer 2 virtual private network (L2VPN), Layer 3 virtual private network (L3VPN), Application Visibility and Control, Performance Routing (PfR), AppNav infrastructure, Data Center Interconnect, Crypto and IPv6
High availability
Provides optional redundant-processor support and dual Cisco IOS Software support for single-route-processor solutions for a highly compact, fully redundant, high-availability solution
Stratum-3 clock circuitry and BITS input ports
Facilitates support of clocking for synchronous services such as SONET and SDH. BITS input ports are available on RP1, RP2 and ASR1002-X only.
Memory scalability of up to 16 GB; up to 64 GB for RP3
Allows pay-as-you-grow scalability so memory can increase as you add more users or features; the scalability offered through memory upgrades includes:
Routing-table growth
Additional MPLS VPN routing and forwarding instances
Feature additions such as SBC and broadband aggregation (BBA)
Routing-table growth
Additional MPLS VPN routing and forwarding instances
Feature additions such as SBC and broadband aggregation (BBA)
Solid state drive support
Allows for greater storage area for code storage, boot, configurations, billing, logs, etc.
USB compact flash support
Allows for easier manageability for code storage, boot, configurations, logs, etc.
Modularity
Offers maximum investment protection and flexibility by allowing customers to upgrade to future Cisco ASR 1000 Series Route Processors
Note: Cisco ASR 1002,and ASR1002-F have an integrated RP1 built into the chassis that is not upgradable.
Note: Cisco ASR 1001, ASR 1001-X, and ASR 1002-X (part numbers ASR 1001, ASR 1001-X, ASR 1002-X) have an integrated RP2 built in to the chassis that is not upgradable.
Note: Cisco ASR 1002,and ASR1002-F have an integrated RP1 built into the chassis that is not upgradable.
Note: Cisco ASR 1001, ASR 1001-X, and ASR 1002-X (part numbers ASR 1001, ASR 1001-X, ASR 1002-X) have an integrated RP2 built in to the chassis that is not upgradable.
Architectural Specifications
Expand
Architectural Specifications
Item
Details
LAN ports
The Cisco ASR 1000 Series RP1, RP2, and RP3 have a single copper (RJ-45) 10/100/1000 management Ethernet port.
For ASR 1001, 1001-X, 1001-HX, 1002, 1002-F, 1002-X, and 1002-HX, the single copper (RJ-45) 10/100/1000 management Ethernet ports are built into the chassis.
For ASR 1001, 1001-X, 1001-HX, 1002, 1002-F, 1002-X, and 1002-HX, the single copper (RJ-45) 10/100/1000 management Ethernet ports are built into the chassis.
SDRAM
The Cisco ASR 1000 Series RP1 can support either 2 or 4 GB of synchronous dynamic RAM (SDRAM). Because the card holds 2 SDRAM slots, a route processor with 2 GB can hold two 1-GB dual in-line memory modules (DIMMs), whereas a route processor with 4 GB can hold two 2-GB DIMMs.
The Cisco ASR 1000 Series RP2 can support either 8 or 16 GB of SDRAM. Because the card holds 4 SDRAM slots, a route processor with 8 GB can hold four 2-GB DIMMs, whereas a route processor with 16 GB can hold four 4-GB DIMMs.
The Cisco ASR 1000 Series RP3 can support either 8, 16, 32, or 64 GB of SDRAM.
The Cisco ASR 1001 and 1002-X built-in route processors support 4, 8, or 16 GB of SDRAM. The Cisco ASR 1001-X built-in route processor supports either 8 GB or 16 GB of SDRAM.
The Cisco ASR 1000 Series RP2 can support either 8 or 16 GB of SDRAM. Because the card holds 4 SDRAM slots, a route processor with 8 GB can hold four 2-GB DIMMs, whereas a route processor with 16 GB can hold four 4-GB DIMMs.
The Cisco ASR 1000 Series RP3 can support either 8, 16, 32, or 64 GB of SDRAM.
The Cisco ASR 1001 and 1002-X built-in route processors support 4, 8, or 16 GB of SDRAM. The Cisco ASR 1001-X built-in route processor supports either 8 GB or 16 GB of SDRAM.
Hard disk drive (HDD)
The Cisco ASR 1000 Series RP1 and RP2 have a HDD for code storage, system configurations, and log files. The RP1 provides a 40-GB HDD mounted on the board itself. The RP1 HDD is field-replaceable, but not hot-swappable. The RP2 provides an 80-GB HDD that is front-mounted, field-replaceable, and hot-swappable. The RP3 provides a 100-GB SSD by default, which is upgradable to 200-GB or 400-GB. The Cisco ASR 1001, 1001-X, 1002, 1002-F, and 1002-X support built-in embedded USB (eUSB) 8 GB memory for code storage, system configurations, and log files. The ASR 1001-X supports an optional solid state drive, and the ASR 1002-X supports an optional HDD for additional code storage, system configurations, and log files.
Solid state drive (SSD)
The Cisco ASR 1001-X supports an optional SSD for additional code storage, system configurations, and log files.
USB port
One USB port is provided on the Cisco ASR 1000 Series RP1, and 2 ports are provided on the RP2 and RP3. All three route processors support 1-GB USB compact flash memory for the storage and portability of operating system software, system configurations, and log files.
Console and auxiliary ports
The Cisco ASR 1000 Series RP1, RP2, and RP3have built-in console and auxiliary ports. The ASR 1001, 1001-X, 1002, 1002-F, and 1002-X have built-in console and auxiliary ports on their respective chassis.
Cisco ASR 1000 Series RP1 Product Specifications
Expand
Cisco ASR 1000 Series RP1 Product Specifications
Item
Item
Details
Chassis support
Cisco ASR 1004 and ASR 1006 chassis
(Note: The Cisco ASR 1002 chassis comes with the Cisco ASR 1000 Series RP1 built into the chassis.)
(Note: Cisco ASR 1001, ASR 1001-X, and ASR 1002-X (part numbers ASR1001, ASR1001-X, ASR1002-X) have an integrated Route Processor built in to the chassis that is not upgradable)
(Note: The Cisco ASR 1002 chassis comes with the Cisco ASR 1000 Series RP1 built into the chassis.)
(Note: Cisco ASR 1001, ASR 1001-X, and ASR 1002-X (part numbers ASR1001, ASR1001-X, ASR1002-X) have an integrated Route Processor built in to the chassis that is not upgradable)
Software compatibility
Cisco IOS XE Operating System, which is based on Cisco IOS Software Release 12.2SR (Please consult your Cisco account representative for additional details.)
Software protocols
Refer to Cisco IOS Software 12.2SR protocol support
Connectivity
Console port (RJ-45 connector)
Auxiliary port (RJ-45 connector)
10/100/1000 Ethernet port (RJ-45 connector)
Two RJ-48 connectors for BITS input clocks
Auxiliary port (RJ-45 connector)
10/100/1000 Ethernet port (RJ-45 connector)
Two RJ-48 connectors for BITS input clocks
Memory options
Two 1-GB Double Data Rate 2 (DDR2) mini-DIMMs
Two 2-GB DDR2 mini-DIMMs
Upgradable memory from 2-GB to 4-GB DRAM
Two 2-GB DDR2 mini-DIMMs
Upgradable memory from 2-GB to 4-GB DRAM
Storage options
40-GB HDD (RP1 only)
1-GB USB Compact Flash memory
1-GB USB Compact Flash memory
Performance
Scalability up to 1,000,000 IPv4 routes or 500,000 IPv6 routes
BGP RR Scalability up to 5,000,000 IPv4 routes or 3,000,000 IPv6 routes
BGP RR Scalability up to 5,000,000 IPv4 routes or 3,000,000 IPv6 routes
Reliability and availability
1 + 1 redundancy in dual-route-processor configuration
Support for online insertion and removal (OIR)
Support for NSF and Stateful Switchover (SSO)
Support for ISSU
Support for online insertion and removal (OIR)
Support for NSF and Stateful Switchover (SSO)
Support for ISSU
MIBs
RFC 2737 compliant
Network management
Telnet and Secure Shell (SSH) Protocol (command-line interface [CLI])
Console port (through the CLI)
Simple Network Management Protocol (SNMP)
RFC 2665
Console port (through the CLI)
Simple Network Management Protocol (SNMP)
RFC 2665
LEDs
PWR - Power
Green - All power rails are within specifications
STAT - Status
Green - Cisco IOS Software has booted
Yellow - BootROM has successfully loaded
Red - System failure or during boot process
ACTV- Active
Green - Active route processor
STBY - Standby
Yellow - Standby route processor
CRIT - Critical
Red - Critical alarm or during boot process
MAJ - Major
Red - Major alarm
MIN - Minor
Amber - Minor alarm
LINK - Management Ethernet link status
Solid green - Link with no activity
FLASH green - Link with activity
Off - No link
DISK0 - Internal Compact Flash
FLASH Green - Activity indicator
Off - No activity
DISK1 - External Compact Flash FLASH green - Activity indicator Off - No activity
DISK2 - Internal HDD FLASH green - Activity indicator Off - No activity
CARRIER - BITS interface Off - Out of service Green - In frame and in service Amber - Fault or loop condition
Green - All power rails are within specifications
STAT - Status
Green - Cisco IOS Software has booted
Yellow - BootROM has successfully loaded
Red - System failure or during boot process
ACTV- Active
Green - Active route processor
STBY - Standby
Yellow - Standby route processor
CRIT - Critical
Red - Critical alarm or during boot process
MAJ - Major
Red - Major alarm
MIN - Minor
Amber - Minor alarm
LINK - Management Ethernet link status
Solid green - Link with no activity
FLASH green - Link with activity
Off - No link
DISK0 - Internal Compact Flash
FLASH Green - Activity indicator
Off - No activity
DISK1 - External Compact Flash FLASH green - Activity indicator Off - No activity
DISK2 - Internal HDD FLASH green - Activity indicator Off - No activity
CARRIER - BITS interface Off - Out of service Green - In frame and in service Amber - Fault or loop condition
Physical dimensions (H x W x D)
0.92 x 16.7 x 14.19 in. (0.02 x 0.428 x 0.36m)
Weight
5.0 lb (2.3 kg)
Approvals and compliance
Safety
UL60950-1 and CAN/CSA-C22.2 No. 60950-1-03 Information technology equipment
AS/NZS 60950-1
IEC/EN 60950-1 Information technology equipment
73/23/EEC
Electromagnetic Emissions Certification
AS/NZ 3548: 1995 (including AMD I + II) Class B
EN55022: 1998 Class B
CISPR 22: 1997
EN55022: 1994 (including AMD I + II)
47 CFR Part 15: 2000 (FCC) Class B
VCCI V-3/01.4 Class 2
CNS-13438: 1997 Class B
GR1089: 1997 (including Rev. 1: 1999)
Immunity
EN300386: 2000-TNE EMC requirements; product family standard; high priority of service; central office and noncentral office locations
EN50082-1: 1992/1997
EN50082-2: 1995-Generic Immunity Standard, Heavy
Industrial
CISPR24: 1997
EN55024: 1998-Generic ITE immunity standard
EN61000-4-2: 1995 + AMD I + II ESD, Level 4/8 kV contact, 15 kV air
IEC-1000-4-3: 1995 + AMD 1-Radiated Immunity, 10 V/m
IEC-1000-4-4: 1995-Electrical Fast Transients, Level 4/4 kV/B
IEC-1000-4-5: 1995 + AMD 1-DC Surge-Class 3; AC Surge-Class 4
EN61000-4-6: 1996 + AMD 1-RF conducted immunity, 10 Vrms
EN61000-4-11: 1995-Voltage Dips and Sags
ETS300 132-2: 1996 + corrigendum, December 1996
GR1089:1997 (including Rev1: 1999)
Network Equipment Building Standards
The module meets the following Networking Equipment Building Standards (NEBS):
GR-1089-CORE
GR-63-CORE
European Telecommunication Standards Institute (ETSI)
ETSI 300 386-1 - Levels for equipment with a "high priority of service" that is installed in "locations other than telecommunication centers"
ETSI 300 386-2:1997 - Levels for equipment with a "high priority of service" that is installed in "locations other than telecommunication centers"
ETSI 300 132-2: December 1994 - Power supply interfaces at the input to telecommunications equipment Sections 4.8 and 4.9
UL60950-1 and CAN/CSA-C22.2 No. 60950-1-03 Information technology equipment
AS/NZS 60950-1
IEC/EN 60950-1 Information technology equipment
73/23/EEC
Electromagnetic Emissions Certification
AS/NZ 3548: 1995 (including AMD I + II) Class B
EN55022: 1998 Class B
CISPR 22: 1997
EN55022: 1994 (including AMD I + II)
47 CFR Part 15: 2000 (FCC) Class B
VCCI V-3/01.4 Class 2
CNS-13438: 1997 Class B
GR1089: 1997 (including Rev. 1: 1999)
Immunity
EN300386: 2000-TNE EMC requirements; product family standard; high priority of service; central office and noncentral office locations
EN50082-1: 1992/1997
EN50082-2: 1995-Generic Immunity Standard, Heavy
Industrial
CISPR24: 1997
EN55024: 1998-Generic ITE immunity standard
EN61000-4-2: 1995 + AMD I + II ESD, Level 4/8 kV contact, 15 kV air
IEC-1000-4-3: 1995 + AMD 1-Radiated Immunity, 10 V/m
IEC-1000-4-4: 1995-Electrical Fast Transients, Level 4/4 kV/B
IEC-1000-4-5: 1995 + AMD 1-DC Surge-Class 3; AC Surge-Class 4
EN61000-4-6: 1996 + AMD 1-RF conducted immunity, 10 Vrms
EN61000-4-11: 1995-Voltage Dips and Sags
ETS300 132-2: 1996 + corrigendum, December 1996
GR1089:1997 (including Rev1: 1999)
Network Equipment Building Standards
The module meets the following Networking Equipment Building Standards (NEBS):
GR-1089-CORE
GR-63-CORE
European Telecommunication Standards Institute (ETSI)
ETSI 300 386-1 - Levels for equipment with a "high priority of service" that is installed in "locations other than telecommunication centers"
ETSI 300 386-2:1997 - Levels for equipment with a "high priority of service" that is installed in "locations other than telecommunication centers"
ETSI 300 132-2: December 1994 - Power supply interfaces at the input to telecommunications equipment Sections 4.8 and 4.9
Environmental
Storage temperature: -38 to 150°F (-40 to 70°C)
Operating temperature, nominal: 41 to 104°F (5 to 40°C)
Operating temperature, short-term: 23 to 131°F (-5 to 55°C)
Storage relative humidity: 5 to 95% relative humidity (RH)
Operating humidity, nominal: 5 to 85% RH
Operating humidity, short-term: 5 to 90% RH
Operating altitude: -60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements)
Operating temperature, nominal: 41 to 104°F (5 to 40°C)
Operating temperature, short-term: 23 to 131°F (-5 to 55°C)
Storage relative humidity: 5 to 95% relative humidity (RH)
Operating humidity, nominal: 5 to 85% RH
Operating humidity, short-term: 5 to 90% RH
Operating altitude: -60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements)
Cisco ASR 1000 Series RP2 Product Specifications
Expand
Cisco ASR 1000 Series RP2 Product Specifications
Item
Item
Details
Chassis support
Cisco ASR 1004, ASR 1006, ASR 1006-X, ASR 1009-X and ASR 1013 chassis
(Note: The Cisco ASR 1002 and ASR 1002 Fixed chassis come with the Cisco ASR 1000 Series RP1 built into the chassis.)
(Note: Cisco ASR 1001, ASR 1001-X, and ASR 1002-X (part numbers ASR1001, ASR1001-X, ASR1002-X) have an integrated Route Processor built in to the chassis that is not upgradable)
(Note: The Cisco ASR 1002 and ASR 1002 Fixed chassis come with the Cisco ASR 1000 Series RP1 built into the chassis.)
(Note: Cisco ASR 1001, ASR 1001-X, and ASR 1002-X (part numbers ASR1001, ASR1001-X, ASR1002-X) have an integrated Route Processor built in to the chassis that is not upgradable)
Software compatibility
Cisco IOS XE Software, which is based on Cisco IOS Software Release 12.2SR
(Please consult your Cisco account representative for additional details.)
(Please consult your Cisco account representative for additional details.)
Software protocols
Refer to Cisco IOS Software 12.2SR protocol support
Connectivity
Console port (RJ-45 connector)
Auxiliary port (RJ-45 connector)
10/100/1000 Ethernet port (RJ-45 connector)
RJ-48 connector for BITS input clock and output source
Auxiliary port (RJ-45 connector)
10/100/1000 Ethernet port (RJ-45 connector)
RJ-48 connector for BITS input clock and output source
Memory options
Four 2-GB DDR2 mini-DIMMs
Four 4 GB DDR2 mini-DIMMs
Upgradable memory from 8-GB to 16-GB DRAM
Four 4 GB DDR2 mini-DIMMs
Upgradable memory from 8-GB to 16-GB DRAM
Storage options
80-GB HDD (hot-swappable)
1-GB USB Compact Flash memory
1-GB USB Compact Flash memory
Performance
With 8-GB memory:
Up to 1,000,000 IPv4 routes or 1,000,000 IPv6 routes
BGP RR Scalability up to 8,000,000 IPv4 routes or 6,000,000 IPv6 routes
With 16-GB memory:
Up to 4,000,000 IPv4 routes or 4,000,000 IPv6 routes
BGP RR Scalability up to 24,000,000 IPv4 routes or 17,000,000 IPv6 routes
Up to 1,000,000 IPv4 routes or 1,000,000 IPv6 routes
BGP RR Scalability up to 8,000,000 IPv4 routes or 6,000,000 IPv6 routes
With 16-GB memory:
Up to 4,000,000 IPv4 routes or 4,000,000 IPv6 routes
BGP RR Scalability up to 24,000,000 IPv4 routes or 17,000,000 IPv6 routes
Reliability and availability
1 + 1 redundancy in dual-route-processor configuration
Support for OIR
Support for NSF and SSO
Support for ISSU
Support for OIR
Support for NSF and SSO
Support for ISSU
MIBs
RFC 2737 compliant
Network management
Telnet and SSH (CLI)
Console port (through the CLI)
SNMP
RFC 2665
Console port (through the CLI)
SNMP
RFC 2665
LEDs
PWR - Power
Green - All power rails are within specifications
STAT - Status
Green - Cisco IOS Software has booted
Yellow - BootROM has successfully loaded
Red - System failure or during boot process
ACTV- Active
Green - Active route processor
STBY - Standby
Yellow - Standby route processor
CRIT - Critical Alarm
Red - Critical alarm or during boot process
MAJ - Major Alarm
Red - Major alarm
MIN - Minor Alarm
Amber - Minor alarm
HD - Internal HDD
FLASH Green - Activity indicator
Off - No activity
USB - External Compact Flash
FLASH green - Activity indicator
BF - Boot Flash (Internal)
FLASH green - Activity indicator
Off - No activity
CARRIER
BITS I/F Mode
Off - Out of service or not configured
Green - Normal or Bridging
Amber - Fast
DTI Mode Off - Warm-up, free-run, or holdover Green - In service or working properly Amber - Fault or loop condition
LINK - Management Ethernet link status Solid green - Link with no activity FLASH green - Link with activity Off - No link
DISK2 - Internal HDD FLASH green - Activity indicator Off - No activity
CARRIER - BITS interface Off - Out of service Green - In frame and in service Amber - Fault or loop condition
Green - All power rails are within specifications
STAT - Status
Green - Cisco IOS Software has booted
Yellow - BootROM has successfully loaded
Red - System failure or during boot process
ACTV- Active
Green - Active route processor
STBY - Standby
Yellow - Standby route processor
CRIT - Critical Alarm
Red - Critical alarm or during boot process
MAJ - Major Alarm
Red - Major alarm
MIN - Minor Alarm
Amber - Minor alarm
HD - Internal HDD
FLASH Green - Activity indicator
Off - No activity
USB - External Compact Flash
FLASH green - Activity indicator
BF - Boot Flash (Internal)
FLASH green - Activity indicator
Off - No activity
CARRIER
BITS I/F Mode
Off - Out of service or not configured
Green - Normal or Bridging
Amber - Fast
DTI Mode Off - Warm-up, free-run, or holdover Green - In service or working properly Amber - Fault or loop condition
LINK - Management Ethernet link status Solid green - Link with no activity FLASH green - Link with activity Off - No link
DISK2 - Internal HDD FLASH green - Activity indicator Off - No activity
CARRIER - BITS interface Off - Out of service Green - In frame and in service Amber - Fault or loop condition
Physical dimensions (H x W x D)
0.92 x 16.7 x 14.19 in. (0.02 x 0.428 x 0.36m)
Weight
5.0 lb (2.3 kg)
Approvals and compliance
Safety
UL60950-1 and CAN/CSA-C22.2 No. 60950-1-03 Information technology equipment
AS/NZS 60950-1
IEC/EN 60950-1 Information technology equipment
73/23/EEC
Electromagnetic Emissions Certification
CFR 47 Part 15: (FCC) Class A
ICES 003 Class A
AS/NZ CISPR 22: Class A
CISPR 22 (EN55022) Class A
VCCI Class A
KN22
IEC/EN 61000-3-2 (or 3-12 as applicable): AC Power Line Harmonics
IEC/EN 61000-3-3 (or 3-11 as applicable): AC Voltage Fluctuations and Flicker
Immunity
IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8-kV Contact, 15-kV Air)
IEC/EN-61000-4-3: Radiated Immunity (10 V/m)
IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2-kV Power, 1-kV Signal)
IEC/EN-61000-4-5: Surge AC Port (4-kV CM, 2-kV DM)
IEC/EN-61000-4-5: Surge Signal Ports (1-kV indoor, 2-kV outdoor)
IEC/EN-61000-4-5: Surge DC Port 1-kV
IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)
IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30 A/m)
IEC/EN-61000-4-11: Voltage Dips, Short Interruptions, and Voltage Variations
Network Equipment Building Standards
The module meets the following NEBS:
GR-1089-CORE
GR-63-CORE
ETSI and EN Standards
EN300 386: Telecommunications Network Equipment (EMC), OTC
EN55022: Information Technology Equipment (Emissions)
EN55024: Information Technology Equipment (Immunity)
EN50082-1/EN-61000-6-1: 1995-Generic Immunity Standard
UL60950-1 and CAN/CSA-C22.2 No. 60950-1-03 Information technology equipment
AS/NZS 60950-1
IEC/EN 60950-1 Information technology equipment
73/23/EEC
Electromagnetic Emissions Certification
CFR 47 Part 15: (FCC) Class A
ICES 003 Class A
AS/NZ CISPR 22: Class A
CISPR 22 (EN55022) Class A
VCCI Class A
KN22
IEC/EN 61000-3-2 (or 3-12 as applicable): AC Power Line Harmonics
IEC/EN 61000-3-3 (or 3-11 as applicable): AC Voltage Fluctuations and Flicker
Immunity
IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8-kV Contact, 15-kV Air)
IEC/EN-61000-4-3: Radiated Immunity (10 V/m)
IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2-kV Power, 1-kV Signal)
IEC/EN-61000-4-5: Surge AC Port (4-kV CM, 2-kV DM)
IEC/EN-61000-4-5: Surge Signal Ports (1-kV indoor, 2-kV outdoor)
IEC/EN-61000-4-5: Surge DC Port 1-kV
IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)
IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30 A/m)
IEC/EN-61000-4-11: Voltage Dips, Short Interruptions, and Voltage Variations
Network Equipment Building Standards
The module meets the following NEBS:
GR-1089-CORE
GR-63-CORE
ETSI and EN Standards
EN300 386: Telecommunications Network Equipment (EMC), OTC
EN55022: Information Technology Equipment (Emissions)
EN55024: Information Technology Equipment (Immunity)
EN50082-1/EN-61000-6-1: 1995-Generic Immunity Standard
Environmental
Storage temperature: -38 to 150°F (-40 to 70°C)
Operating temperature, nominal: 41 to 104°F (5 to 40°C)
Operating temperature, short-term: 23 to 131°F (-5 to 55°C)
Storage relative humidity: 5 to 95% RH
Operating humidity, nominal: 5 to 85% RH
Operating humidity, short-term: 5 to 90% RH
Operating altitude: -60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements)
Operating temperature, nominal: 41 to 104°F (5 to 40°C)
Operating temperature, short-term: 23 to 131°F (-5 to 55°C)
Storage relative humidity: 5 to 95% RH
Operating humidity, nominal: 5 to 85% RH
Operating humidity, short-term: 5 to 90% RH
Operating altitude: -60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements)
Cisco ASR 1000 Series RP3 Product Specifications
Expand
Cisco ASR 1000 Series RP3 Product Specifications
Item
Item
Details
Chassis support
Cisco ASR 1006-X, 1009-X, and 1013 chassis
Software compatibility
Minimum Cisco IOS XE 16.3.1 Software
(Please consult your Cisco account representative for additional details.)
(Please consult your Cisco account representative for additional details.)
Software protocols
Refer to Cisco IOS XE 16.3.1 and later versions for protocol support
Connectivity
Console port (RJ-45 connector)
Auxiliary port (RJ-45 connector)
10/100/1000 Ethernet port (RJ-45 connector)
RJ-48 connector for BITS input clock and output source
Auxiliary port (RJ-45 connector)
10/100/1000 Ethernet port (RJ-45 connector)
RJ-48 connector for BITS input clock and output source
Memory options
8-GB memory default; upgradable to 16-GB, 32-GB, or 64-GB memory
Storage options
100-GB SSD (hot-swappable); upgradable to 200-GB or 400-GB SSD
1-GB USB compact flash memory
1-GB USB compact flash memory
Performance
With 8-GB memory:
Up to 1,000,000 IPv4 routes or 1,000,000 IPv6 routes
BGP RR scalability up to 8,000,000 IPv4 routes or 6,000,000 IPv6 routes
With 16-GB memory:
Up to 4,000,000 IPv4 routes or 4,000,000 IPv6 routes
BGP RR scalability up to 24,000,000 IPv4 routes or 17,000,000 IPv6 routes
With 32-GB memory:
Up to 8,500,000 IPv4 routes or 7,500,000 IPv6 routes
BGP RR scalability up to 24,000,000 IPv4 routes or 17,000,000 IPv6 routes
Up to 1,000,000 IPv4 routes or 1,000,000 IPv6 routes
BGP RR scalability up to 8,000,000 IPv4 routes or 6,000,000 IPv6 routes
With 16-GB memory:
Up to 4,000,000 IPv4 routes or 4,000,000 IPv6 routes
BGP RR scalability up to 24,000,000 IPv4 routes or 17,000,000 IPv6 routes
With 32-GB memory:
Up to 8,500,000 IPv4 routes or 7,500,000 IPv6 routes
BGP RR scalability up to 24,000,000 IPv4 routes or 17,000,000 IPv6 routes
Reliability and availability
1 + 1 redundancy in dual-route-processor configuration
Support for OIR
Support for NSF and SSO
Support for ISSU
Support for OIR
Support for NSF and SSO
Support for ISSU
MIBs
RFC 2737 compliant
Network management
Telnet and SSH (CLI)
Console port (through the CLI)
SNMP
RFC 2665
Console port (through the CLI)
SNMP
RFC 2665
Physical dimensions (H x W x D)
Physical dimensions (H x W x D)
0.92 x 16.7 x 14.19 in. (0.02 x 0.428 x 0.36m)
Weight
7 lb (3.2 kg)
Approvals and compliance
Safety
UL60950-1 and CAN/CSA-C22.2 No. 60950-1-03 Information technology equipment
AS/NZS 60950-1
IEC/EN 60950-1 Information technology equipment
73/23/EEC
Electromagnetic Emissions Certification
CFR 47 Part 15: (FCC) Class A
ICES 003 Class A
AS/NZ CISPR 22: Class A
CISPR 22 (EN55022) Class A
VCCI Class A
KN22
IEC/EN 61000-3-2 (or 3-12 as applicable): AC Power Line Harmonics
IEC/EN 61000-3-3 (or 3-11 as applicable): AC Voltage Fluctuations and Flicker
Immunity
IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8-kV Contact, 15-kV Air)
IEC/EN-61000-4-3: Radiated Immunity (10 V/m)
IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2-kV Power, 1-kV Signal)
IEC/EN-61000-4-5: Surge AC Port (4-kV CM, 2-kV DM)
IEC/EN-61000-4-5: Surge Signal Ports (1-kV indoor, 2-kV outdoor)
IEC/EN-61000-4-5: Surge DC Port 1-kV
IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)
IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30 A/m)
IEC/EN-61000-4-11: Voltage Dips, Short Interruptions, and Voltage Variations
Network Equipment Building Standards
The module meets the following NEBS:
GR-1089-CORE
GR-63-CORE
ETSI and EN Standards
EN300 386: Telecommunications Network Equipment (EMC), OTC
EN55022: Information Technology Equipment (Emissions)
EN55024: Information Technology Equipment (Immunity)
EN50082-1/EN-61000-6-1: 1995-Generic Immunity Standard
UL60950-1 and CAN/CSA-C22.2 No. 60950-1-03 Information technology equipment
AS/NZS 60950-1
IEC/EN 60950-1 Information technology equipment
73/23/EEC
Electromagnetic Emissions Certification
CFR 47 Part 15: (FCC) Class A
ICES 003 Class A
AS/NZ CISPR 22: Class A
CISPR 22 (EN55022) Class A
VCCI Class A
KN22
IEC/EN 61000-3-2 (or 3-12 as applicable): AC Power Line Harmonics
IEC/EN 61000-3-3 (or 3-11 as applicable): AC Voltage Fluctuations and Flicker
Immunity
IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8-kV Contact, 15-kV Air)
IEC/EN-61000-4-3: Radiated Immunity (10 V/m)
IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2-kV Power, 1-kV Signal)
IEC/EN-61000-4-5: Surge AC Port (4-kV CM, 2-kV DM)
IEC/EN-61000-4-5: Surge Signal Ports (1-kV indoor, 2-kV outdoor)
IEC/EN-61000-4-5: Surge DC Port 1-kV
IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)
IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30 A/m)
IEC/EN-61000-4-11: Voltage Dips, Short Interruptions, and Voltage Variations
Network Equipment Building Standards
The module meets the following NEBS:
GR-1089-CORE
GR-63-CORE
ETSI and EN Standards
EN300 386: Telecommunications Network Equipment (EMC), OTC
EN55022: Information Technology Equipment (Emissions)
EN55024: Information Technology Equipment (Immunity)
EN50082-1/EN-61000-6-1: 1995-Generic Immunity Standard
Environmental
Storage temperature: -38 to 150°F (-40 to 70°C)
Operating temperature, nominal: 41 to 104°F (5 to 40°C)
Operating temperature, short-term: 23 to 131°F (-5 to 55°C)
Storage relative humidity: 5 to 95% RH
Operating humidity, nominal: 5 to 85% RH
Operating humidity, short-term: 5 to 90% RH
Operating altitude: -60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements)
Operating temperature, nominal: 41 to 104°F (5 to 40°C)
Operating temperature, short-term: 23 to 131°F (-5 to 55°C)
Storage relative humidity: 5 to 95% RH
Operating humidity, nominal: 5 to 85% RH
Operating humidity, short-term: 5 to 90% RH
Operating altitude: -60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements)
Cisco ASR 1001 Integrated Route Processor Product Specifications
Expand
Cisco ASR 1001 Integrated Route Processor Product Specifications
Item
Item
Details
Chassis support
Cisco ASR 1001 chassis
Software compatibility
Cisco IOS XE Software Release 3.2.0S and later versions
Software protocols
Refer to Cisco IOS XE 3.2.0S and later versions for protocol support
Connectivity
Not applicable - route processor is integrated inside the chassis
Memory options
Cisco ASR 1001 ships with 4-GB memory by default. It can be upgraded to 8- or 16-GB memory
Cisco ASR 1001 has 4 DRAM memory slots, which can take either 2- or 4-GB DRAM each
When shipped with 4-GB DRAM (M-ASR1K-1001-4 GB), 2 slots are filled with 2 GB each
When shipped with 8-GB DRAM (M-ASR1K-1001-8 GB), 4 slots are filled with 2 GB each
When shipped with 16-GB DRAM (M-ASR1K-1001-16 GB), 4 slots are filled with 4 GB each
Cisco ASR 1001 has 4 DRAM memory slots, which can take either 2- or 4-GB DRAM each
When shipped with 4-GB DRAM (M-ASR1K-1001-4 GB), 2 slots are filled with 2 GB each
When shipped with 8-GB DRAM (M-ASR1K-1001-8 GB), 4 slots are filled with 2 GB each
When shipped with 16-GB DRAM (M-ASR1K-1001-16 GB), 4 slots are filled with 4 GB each
Storage options
8-GB eUSB is partitioned as two 32-MB of memory for nonvolatile RAM (NVRAM) and the rest for mass storage
The Cisco ASR 1001-HDD model includes 160-GB HDD for storage
The Cisco ASR 1001-HDD model includes 160-GB HDD for storage
Performance
With 4-GB memory:
Up to 500,000 IPv4 or 500,000 IPv6 routes
With 8-GB or 16-GB memory:
Up to 1,000,000 IPv4 or 1,000,000 IPv6 routes
BGP RR Scalability up to 5,250,000 IPv4 or 4,250,000 IPv6 routes - 8 GB Memory
BGP RR Scalability up to 11,500,000 IPv4 or 10,000,000 IPv6 routes - 16 GB Memory
Up to 500,000 IPv4 or 500,000 IPv6 routes
With 8-GB or 16-GB memory:
Up to 1,000,000 IPv4 or 1,000,000 IPv6 routes
BGP RR Scalability up to 5,250,000 IPv4 or 4,250,000 IPv6 routes - 8 GB Memory
BGP RR Scalability up to 11,500,000 IPv4 or 10,000,000 IPv6 routes - 16 GB Memory
Reliability and availability
No route-processor hardware redundancy
Software redundancy available (requires software redundancy license and 8-GB memory)
Software redundancy available (requires software redundancy license and 8-GB memory)
MIBs
RFC 2737 compliant
Network management
Telnet and SSH Protocol (CLI)
Console port (through the CLI)
SNMP
RFC 2665
Console port (through the CLI)
SNMP
RFC 2665
LEDs
PWR - Power Green - All power rails are within specifications
STAT - Status Green - Cisco IOS Software has booted Yellow - BootROM has successfully loaded Red - System failure or during boot process
ACTV- Active Green - Active route processor
STBY - Standby Yellow - Standby route processor
CRIT - Critical Alarm Red - Critical alarm or during boot process
MAJ - Major Alarm Red - Major alarm
MIN - Minor Alarm Amber - Minor alarm
HD - Internal HDD FLASH Green - Activity indicator Off - No activity
USB - External Compact Flash FLASH green - Activity indicator
BF - Boot Flash (Internal) FLASH green - Activity indicator Off - No activity
CARRIER BITS I/F Mode Off- Out of service or not configured Green - Normal or Bridging Amber - Fast
DTI Mode Off- Warm-up, free-run, or holdover Green - In service or working properly Amber - Fault or loop condition
LINK - Management Ethernet link status Solid green - Link with no activity FLASH green - Link with activity Off - No link
DISK2 - Internal HDD FLASH green - Activity indicator Off - No activity
CARRIER - BITS interface Off - Out of service Green - In frame and in service Amber - Fault or loop condition
STAT - Status Green - Cisco IOS Software has booted Yellow - BootROM has successfully loaded Red - System failure or during boot process
ACTV- Active Green - Active route processor
STBY - Standby Yellow - Standby route processor
CRIT - Critical Alarm Red - Critical alarm or during boot process
MAJ - Major Alarm Red - Major alarm
MIN - Minor Alarm Amber - Minor alarm
HD - Internal HDD FLASH Green - Activity indicator Off - No activity
USB - External Compact Flash FLASH green - Activity indicator
BF - Boot Flash (Internal) FLASH green - Activity indicator Off - No activity
CARRIER BITS I/F Mode Off- Out of service or not configured Green - Normal or Bridging Amber - Fast
DTI Mode Off- Warm-up, free-run, or holdover Green - In service or working properly Amber - Fault or loop condition
LINK - Management Ethernet link status Solid green - Link with no activity FLASH green - Link with activity Off - No link
DISK2 - Internal HDD FLASH green - Activity indicator Off - No activity
CARRIER - BITS interface Off - Out of service Green - In frame and in service Amber - Fault or loop condition
Approvals and compliance
Safety
UL60950-1 and CAN/CSA-C22.2 No. 60950-1-03 Information technology equipment
AS/NZS 60950-1
IEC/EN 60950-1 Information technology equipment
73/23/EEC
Electromagnetic Emissions Certification
CFR 47 Part 15: (FCC) Class A
ICES 003 Class A
AS/NZ CISPR 22: Class A
CISPR 22 (EN55022) Class A
VCCI Class A
KN22
IEC/EN 61000-3-2 (or 3-12 as applicable): AC Power Line Harmonics
IEC/EN 61000-3-3 (or 3-11 as applicable): AC Voltage Fluctuations and Flicker
Immunity
IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8-kV Contact, 15-kV Air)
IEC/EN-61000-4-3: Radiated Immunity (10 V/m)
IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2-kV Power, 1-kV Signal)
IEC/EN-61000-4-5: Surge AC Port (4-kV CM, 2-kV DM)
IEC/EN-61000-4-5: Surge Signal Ports (1-kV indoor, 2-kV outdoor)
IEC/EN-61000-4-5: Surge DC Port 1-kV
IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)
IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30 A/m)
IEC/EN-61000-4-11: Voltage Dips, Short Interruptions, and Voltage Variations
ETSI and EN Standards
EN300 386: Telecommunications Network Equipment (EMC), OTC
EN55022: Information Technology Equipment (Emissions)
EN55024: Information Technology Equipment (Immunity)
EN50082-1/EN-61000-6-1: 1995-Generic Immunity Standard
UL60950-1 and CAN/CSA-C22.2 No. 60950-1-03 Information technology equipment
AS/NZS 60950-1
IEC/EN 60950-1 Information technology equipment
73/23/EEC
Electromagnetic Emissions Certification
CFR 47 Part 15: (FCC) Class A
ICES 003 Class A
AS/NZ CISPR 22: Class A
CISPR 22 (EN55022) Class A
VCCI Class A
KN22
IEC/EN 61000-3-2 (or 3-12 as applicable): AC Power Line Harmonics
IEC/EN 61000-3-3 (or 3-11 as applicable): AC Voltage Fluctuations and Flicker
Immunity
IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8-kV Contact, 15-kV Air)
IEC/EN-61000-4-3: Radiated Immunity (10 V/m)
IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2-kV Power, 1-kV Signal)
IEC/EN-61000-4-5: Surge AC Port (4-kV CM, 2-kV DM)
IEC/EN-61000-4-5: Surge Signal Ports (1-kV indoor, 2-kV outdoor)
IEC/EN-61000-4-5: Surge DC Port 1-kV
IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)
IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30 A/m)
IEC/EN-61000-4-11: Voltage Dips, Short Interruptions, and Voltage Variations
ETSI and EN Standards
EN300 386: Telecommunications Network Equipment (EMC), OTC
EN55022: Information Technology Equipment (Emissions)
EN55024: Information Technology Equipment (Immunity)
EN50082-1/EN-61000-6-1: 1995-Generic Immunity Standard
Environmental
Storage temperature: -38 to 150°F (-40 to 70°C)
Operating temperature, nominal: 41 to 104°F (5 to 40°C)
Operating temperature, short-term: 23 to 131°F (-5 to 55°C)
Storage relative humidity: 5 to 95% RH
Operating humidity, nominal: 5 to 85% RH
Operating humidity, short-term: 5 to 90% RH
Operating altitude: -60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements)
Operating temperature, nominal: 41 to 104°F (5 to 40°C)
Operating temperature, short-term: 23 to 131°F (-5 to 55°C)
Storage relative humidity: 5 to 95% RH
Operating humidity, nominal: 5 to 85% RH
Operating humidity, short-term: 5 to 90% RH
Operating altitude: -60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements)
Cisco ASR 1001-X Integrated Route Processor Product Specifications
Expand
Cisco ASR 1001-X Integrated Route Processor Product Specifications
Item
Item
Details
Chassis support
Cisco ASR 1001-X chassis
Software compatibility
Cisco IOS XE Software Release 3.12.0S and later versions
Software protocols
Refer to Cisco IOS XE 3.12.0S and later versions for protocol support
Connectivity
Not applicable - route processor is integrated inside the chassis
Memory options
Cisco ASR 1001-X ships with 8-GB memory by default. It can be upgraded 16-GB memory
Cisco ASR 1001-X has 2 DRAM memory slots, which can take either 4- or 8-GB DRAM each
When shipped with 8-GB DRAM (M-ASR1001X-8 GB), 2 slots are filled with 4 GB each
When shipped with 16-GB DRAM (M-ASR1001X-16 GB), 2 slots are filled with 8 GB each
Cisco ASR 1001-X has 2 DRAM memory slots, which can take either 4- or 8-GB DRAM each
When shipped with 8-GB DRAM (M-ASR1001X-8 GB), 2 slots are filled with 4 GB each
When shipped with 16-GB DRAM (M-ASR1001X-16 GB), 2 slots are filled with 8 GB each
Performance
Performance
With 8-GB or 16-GB memory:
Up to 1,000,000 IPv4 or 1,000,000 IPv6 routes - 8 GB Memory
Up to 3,500,000 IPv4 or 3,000,000 IPv6 routes - 16 GB Memory
BGP RR Scalability up to 5,250,000 IPv4 or 4,250,000 IPv6 routes - 8 GB Memory
BGP RR Scalability up to 11,500,000 IPv4 or 10,000,000 IPv6 routes - 16 GB Memory
Up to 1,000,000 IPv4 or 1,000,000 IPv6 routes - 8 GB Memory
Up to 3,500,000 IPv4 or 3,000,000 IPv6 routes - 16 GB Memory
BGP RR Scalability up to 5,250,000 IPv4 or 4,250,000 IPv6 routes - 8 GB Memory
BGP RR Scalability up to 11,500,000 IPv4 or 10,000,000 IPv6 routes - 16 GB Memory
Reliability and availability
No route-processor hardware redundancy
Software redundancy available (requires software redundancy license and 8-GB memory)
Software redundancy available (requires software redundancy license and 8-GB memory)
MIBs
RFC 2737 compliant
Network management
Telnet and SSH Protocol (CLI)
Console port (through the CLI)
SNMP
RFC 2665
Console port (through the CLI)
SNMP
RFC 2665
LEDs
PWR – Power
Green - All power rails are within specifications
STAT – Status
Green - Cisco IOS Software has booted Yellow - BootROM has successfully loaded Red - System failure or during boot process
ACTV- Active Green - Active route processor
STBY - Standby Yellow - Standby route processor
CRIT - Critical Alarm Red - Critical alarm or during boot process
MAJ - Major Alarm Red - Major alarm
MIN - Minor Alarm Amber - Minor alarm
HD - Internal HDD FLASH Green - Activity indicator Off - No activity
USB - External Compact Flash FLASH green - Activity indicator
BF - Boot Flash (Internal) FLASH green - Activity indicator Off - No activity
CARRIER BITS I/F Mode Off- Out of service or not configured Green - Normal or Bridging Amber - Fast
DTI Mode Off- Warm-up, free-run, or holdover Green - In service or working properly Amber - Fault or loop condition
LINK - Management Ethernet link status Solid green - Link with no activity FLASH green - Link with activity Off - No link
DISK2 - Internal HDD FLASH green - Activity indicator Off - No activity
CARRIER - BITS interface Off - Out of service Green - In frame and in service Amber - Fault or loop condition
Green - All power rails are within specifications
STAT – Status
Green - Cisco IOS Software has booted Yellow - BootROM has successfully loaded Red - System failure or during boot process
ACTV- Active Green - Active route processor
STBY - Standby Yellow - Standby route processor
CRIT - Critical Alarm Red - Critical alarm or during boot process
MAJ - Major Alarm Red - Major alarm
MIN - Minor Alarm Amber - Minor alarm
HD - Internal HDD FLASH Green - Activity indicator Off - No activity
USB - External Compact Flash FLASH green - Activity indicator
BF - Boot Flash (Internal) FLASH green - Activity indicator Off - No activity
CARRIER BITS I/F Mode Off- Out of service or not configured Green - Normal or Bridging Amber - Fast
DTI Mode Off- Warm-up, free-run, or holdover Green - In service or working properly Amber - Fault or loop condition
LINK - Management Ethernet link status Solid green - Link with no activity FLASH green - Link with activity Off - No link
DISK2 - Internal HDD FLASH green - Activity indicator Off - No activity
CARRIER - BITS interface Off - Out of service Green - In frame and in service Amber - Fault or loop condition
Approvals and compliance
Safety
UL60950-1 and CAN/CSA-C22.2 No. 60950-1-03 Information technology equipment
AS/NZS 60950-1
IEC/EN 60950-1 Information technology equipment
73/23/EEC
Electromagnetic Emissions Certification
CFR 47 Part 15: (FCC) Class A
ICES 003 Class A
AS/NZ CISPR 22: Class A
CISPR 22 (EN55022) Class A
VCCI Class A
KN22
IEC/EN 61000-3-2 (or 3-12 as applicable): AC Power Line Harmonics
IEC/EN 61000-3-3 (or 3-11 as applicable): AC Voltage Fluctuations and Flicker
Immunity
IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8-kV Contact, 15-kV Air)
IEC/EN-61000-4-3: Radiated Immunity (10 V/m)
IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2-kV Power, 1-kV Signal)
IEC/EN-61000-4-5: Surge AC Port (4-kV CM, 2-kV DM)
IEC/EN-61000-4-5: Surge Signal Ports (1-kV indoor, 2-kV outdoor)
IEC/EN-61000-4-5: Surge DC Port 1-kV
IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)
IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30 A/m)
IEC/EN-61000-4-11: Voltage Dips, Short Interruptions, and Voltage Variations
ETSI and EN Standards
EN300 386: Telecommunications Network Equipment (EMC), OTC
EN55022: Information Technology Equipment (Emissions)
EN55024: Information Technology Equipment (Immunity)
EN50082-1/EN-61000-6-1: 1995-Generic Immunity Standard
UL60950-1 and CAN/CSA-C22.2 No. 60950-1-03 Information technology equipment
AS/NZS 60950-1
IEC/EN 60950-1 Information technology equipment
73/23/EEC
Electromagnetic Emissions Certification
CFR 47 Part 15: (FCC) Class A
ICES 003 Class A
AS/NZ CISPR 22: Class A
CISPR 22 (EN55022) Class A
VCCI Class A
KN22
IEC/EN 61000-3-2 (or 3-12 as applicable): AC Power Line Harmonics
IEC/EN 61000-3-3 (or 3-11 as applicable): AC Voltage Fluctuations and Flicker
Immunity
IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8-kV Contact, 15-kV Air)
IEC/EN-61000-4-3: Radiated Immunity (10 V/m)
IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2-kV Power, 1-kV Signal)
IEC/EN-61000-4-5: Surge AC Port (4-kV CM, 2-kV DM)
IEC/EN-61000-4-5: Surge Signal Ports (1-kV indoor, 2-kV outdoor)
IEC/EN-61000-4-5: Surge DC Port 1-kV
IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)
IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30 A/m)
IEC/EN-61000-4-11: Voltage Dips, Short Interruptions, and Voltage Variations
ETSI and EN Standards
EN300 386: Telecommunications Network Equipment (EMC), OTC
EN55022: Information Technology Equipment (Emissions)
EN55024: Information Technology Equipment (Immunity)
EN50082-1/EN-61000-6-1: 1995-Generic Immunity Standard
Environmental
Storage temperature: -38 to 150°F (-40 to 70°C)
Operating temperature, nominal: 32 to 104°F (0 to 40°C)
Operating temperature, short-term: 32 to 131°F (0 to 55°C)
Storage relative humidity: 5 to 95% RH
Operating humidity, nominal: 10 to 90% RH
Operating humidity, short-term: 5 to 95% RH
Operating altitude: -60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements)
Operating temperature, nominal: 32 to 104°F (0 to 40°C)
Operating temperature, short-term: 32 to 131°F (0 to 55°C)
Storage relative humidity: 5 to 95% RH
Operating humidity, nominal: 10 to 90% RH
Operating humidity, short-term: 5 to 95% RH
Operating altitude: -60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements)
Cisco ASR 1002-X Integrated Route Processor Product Specifications
Expand
Cisco ASR 1002-X Integrated Route Processor Product Specifications
Item
Item
Details
Chassis support
Cisco ASR 1002-X chassis
Software compatibility
Cisco IOS XE Software Release 3.7.0S and later versions
Software protocols
Refer to Cisco IOS XE 3.7.0S and later versions for protocol support
Connectivity
Not applicable - route processor is integrated inside the chassis
Memory options
Cisco ASR 1002-X ships with 4-GB memory by default. It can be upgraded to 8- or 16-GB memory
Cisco ASR 1002-X has 4 DRAM memory slots, which can take either 2- or 4-GB DRAM each
When shipped with 4-GB DRAM (M-ASR1002X-4 GB), 2 slots are filled with 2 GB each
When shipped with 8-GB DRAM (M-ASR1002X-8 GB), 4 slots are filled with 2 GB each
When shipped with 16-GB DRAM (M-ASR1002X-16 GB), 4 slots are filled with 4 GB each
Cisco ASR 1002-X has 4 DRAM memory slots, which can take either 2- or 4-GB DRAM each
When shipped with 4-GB DRAM (M-ASR1002X-4 GB), 2 slots are filled with 2 GB each
When shipped with 8-GB DRAM (M-ASR1002X-8 GB), 4 slots are filled with 2 GB each
When shipped with 16-GB DRAM (M-ASR1002X-16 GB), 4 slots are filled with 4 GB each
Storage options
8-GB eUSB memory is partitioned as two 32-MB of memory for NVRAM and the rest for mass storage
The Cisco ASR 1002-X has an optional 160-GB HDD for storage
The Cisco ASR 1002-X has an optional 160-GB HDD for storage
Performance
With 4-GB memory:
Up to 500,000 IPv4 or 500,000 IPv6 routes
With 8-GB or 16-GB memory:
Up to 1,000,000 IPv4 or 1,000,000 IPv6 routes - 8 GB Memory
Up to 3,500,000 IPv4 or 3,000,000 IPv6 routes - 16 GB Memory
BGP RR Scalability up to 5,250,000 IPv4 or 4,250,000 IPv6 routes - 8 GB Memory
BGP RR Scalability up to 11,500,000 IPv4 or 10,000,000 IPv6 routes - 16 GB Memory
Up to 500,000 IPv4 or 500,000 IPv6 routes
With 8-GB or 16-GB memory:
Up to 1,000,000 IPv4 or 1,000,000 IPv6 routes - 8 GB Memory
Up to 3,500,000 IPv4 or 3,000,000 IPv6 routes - 16 GB Memory
BGP RR Scalability up to 5,250,000 IPv4 or 4,250,000 IPv6 routes - 8 GB Memory
BGP RR Scalability up to 11,500,000 IPv4 or 10,000,000 IPv6 routes - 16 GB Memory
Reliability and availability
No route-processor hardware redundancy
Software redundancy available (requires software redundancy license and 8-GB memory)
Software redundancy available (requires software redundancy license and 8-GB memory)
MIBs
RFC 2737 compliant
Network management
Telnet and SSH Protocol (CLI)
Console port (through the CLI)
SNMP
RFC 2665
Console port (through the CLI)
SNMP
RFC 2665
LEDs
PWR – Power Green - All power rails are within specifications
STAT - Status Green - Cisco IOS Software has booted Yellow - BootROM has successfully loaded Red - System failure or during boot process
CRIT - Critical Alarm Red - Critical alarm or during boot process
MAJ - Major Alarm Red - Major alarm
MIN - Minor Alarm Amber - Minor alarm
LINK - Management Ethernet link status Solid green - Link with no activity FLASH green - Link with activity Off - No link
BOOT FLASH Green - Activity indicator Off - No activity
BITS Off- Out of service or not configured Green - In frame and In service Amber - Fault condition
HDD FLASH green - Activity indicator
GPS Off- Port not connected Green - In service or working properly Amber - Fault condition
STAT - Status Green - Cisco IOS Software has booted Yellow - BootROM has successfully loaded Red - System failure or during boot process
CRIT - Critical Alarm Red - Critical alarm or during boot process
MAJ - Major Alarm Red - Major alarm
MIN - Minor Alarm Amber - Minor alarm
LINK - Management Ethernet link status Solid green - Link with no activity FLASH green - Link with activity Off - No link
BOOT FLASH Green - Activity indicator Off - No activity
BITS Off- Out of service or not configured Green - In frame and In service Amber - Fault condition
HDD FLASH green - Activity indicator
GPS Off- Port not connected Green - In service or working properly Amber - Fault condition
Approvals and compliance
Safety
UL60950-1 and CAN/CSA-C22.2 No. 60950-1-03 Information technology equipment
AS/NZS 60950-1
IEC/EN 60950-1 Information technology equipment
73/23/EEC
Electromagnetic Emissions Certification
CFR 47 Part 15: (FCC) Class A
ICES 003 Class A
AS/NZ CISPR 22: Class A
CISPR 22 (EN55022) Class A
VCCI Class A
KN22
IEC/EN 61000-3-2 (or 3-12 as applicable): AC Power Line Harmonics
IEC/EN 61000-3-3 (or 3-11 as applicable): AC Voltage Fluctuations and Flicker
Immunity
IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8-kV Contact, 15-kV Air)
IEC/EN-61000-4-3: Radiated Immunity (10 V/m)
IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2-kV Power, 1-kV Signal)
IEC/EN-61000-4-5: Surge AC Port (4-kV CM, 2-kV DM)
IEC/EN-61000-4-5: Surge Signal Ports (1-kV indoor, 2-kV outdoor)
IEC/EN-61000-4-5: Surge DC Port 1-kV
IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)
IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30 A/m)
IEC/EN-61000-4-11: Voltage Dips, Short Interruptions, and Voltage Variations
Network Equipment Building Standards
The module meets the following NEBS:
GR-1089-CORE
GR-63-CORE
ETSI and EN Standards
EN300 386: Telecommunications Network Equipment (EMC), OTC
EN55022: Information Technology Equipment (Emissions)
EN55024: Information Technology Equipment (Immunity)
EN50082-1/EN-61000-6-1: 1995-Generic Immunity Standard
UL60950-1 and CAN/CSA-C22.2 No. 60950-1-03 Information technology equipment
AS/NZS 60950-1
IEC/EN 60950-1 Information technology equipment
73/23/EEC
Electromagnetic Emissions Certification
CFR 47 Part 15: (FCC) Class A
ICES 003 Class A
AS/NZ CISPR 22: Class A
CISPR 22 (EN55022) Class A
VCCI Class A
KN22
IEC/EN 61000-3-2 (or 3-12 as applicable): AC Power Line Harmonics
IEC/EN 61000-3-3 (or 3-11 as applicable): AC Voltage Fluctuations and Flicker
Immunity
IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8-kV Contact, 15-kV Air)
IEC/EN-61000-4-3: Radiated Immunity (10 V/m)
IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2-kV Power, 1-kV Signal)
IEC/EN-61000-4-5: Surge AC Port (4-kV CM, 2-kV DM)
IEC/EN-61000-4-5: Surge Signal Ports (1-kV indoor, 2-kV outdoor)
IEC/EN-61000-4-5: Surge DC Port 1-kV
IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)
IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30 A/m)
IEC/EN-61000-4-11: Voltage Dips, Short Interruptions, and Voltage Variations
Network Equipment Building Standards
The module meets the following NEBS:
GR-1089-CORE
GR-63-CORE
ETSI and EN Standards
EN300 386: Telecommunications Network Equipment (EMC), OTC
EN55022: Information Technology Equipment (Emissions)
EN55024: Information Technology Equipment (Immunity)
EN50082-1/EN-61000-6-1: 1995-Generic Immunity Standard
Environmental
Storage temperature: -38 to 150°F (-40 to 70°C)
Operating temperature, nominal: 41 to 104°F (5 to 40°C)
Operating temperature, short-term: 23 to 131°F (-5 to 55°C)
Storage relative humidity: 5 to 95% relative humidity (RH)
Operating humidity, nominal: 5 to 85% RH
Operating humidity, short-term: 5 to 90% RH
Operating altitude: -60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements)
Operating temperature, nominal: 41 to 104°F (5 to 40°C)
Operating temperature, short-term: 23 to 131°F (-5 to 55°C)
Storage relative humidity: 5 to 95% relative humidity (RH)
Operating humidity, nominal: 5 to 85% RH
Operating humidity, short-term: 5 to 90% RH
Operating altitude: -60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements)
Cisco ASR 1000 Series RP1, RP2, and RP3 System Requirements
Expand
Cisco ASR 1000 Series RP1, RP2, and RP3 System Requirements
Item
Details
Hardware
Cisco ASR 1000 Series RP1
Cisco ASR 1004 and 1006
Cisco ASR 1000 Series RP2
Cisco ASR 1004, 1006, 1006-X, 1009-X, and 1013
Cisco ASR 1000 Series RP3
Cisco ASR 1006-X, 1009-X, and 1013
Cisco ASR 1004 and 1006
Cisco ASR 1000 Series RP2
Cisco ASR 1004, 1006, 1006-X, 1009-X, and 1013
Cisco ASR 1000 Series RP3
Cisco ASR 1006-X, 1009-X, and 1013
Memory
Cisco ASR 1000 Series RP1
4 GB (default for RP1)
Cisco ASR 1000 Series RP2
8 GB (default for RP2)
16 GB (maximum RP2)
Note: Memory is field-upgradable from 8 to 16 GB.
Cisco ASR 1000 Series RP3
8 GB (default for RP3)
16 GB
32 GB
64 GB (maximum for RP3)
Note: Memory is field-upgradable from 8 to 64 GB.
4 GB (default for RP1)
Cisco ASR 1000 Series RP2
8 GB (default for RP2)
16 GB (maximum RP2)
Note: Memory is field-upgradable from 8 to 16 GB.
Cisco ASR 1000 Series RP3
8 GB (default for RP3)
16 GB
32 GB
64 GB (maximum for RP3)
Note: Memory is field-upgradable from 8 to 64 GB.
Minimum software release
Cisco ASR 1000 Series RP1
Cisco IOS XE Software Release 2.1.0
Cisco ASR 1000 Series RP2
Cisco IOS XE Software Release 2.3.0
Cisco ASR 1000 Series RP3
Cisco IOS XE Software Release 16.3.1
Cisco IOS XE Software Release 2.1.0
Cisco ASR 1000 Series RP2
Cisco IOS XE Software Release 2.3.0
Cisco ASR 1000 Series RP3
Cisco IOS XE Software Release 16.3.1
Refurbished CISCO M-ASR1K-SSD-200GB datasheet
Download PDF
Why Buy Refurbished?
Why Go Communications?
Related Products

CISCO
800-30508-01
Cisco ASR 1000 RP HDD/SSD Storage Caddy
800-30508-01
- Availability:
- Not In Stock
- Lead Time:
- 2-3 Days

CISCO
800-102578-01
200GB 2.5in 6Gbps Read Intensive 3-DWPD MLC SATA / Serial ATA eSSD
800-102578-01
- Availability:
- Not In Stock
- Lead Time:
- 2-3 Days