Description
The M9XT-FC1632 is a product offered by CISCO, a technology company. This product is a Fibre Channel switch that is designed to improve the performance of storage area networks (SANs). It has 16 gigabit per second (Gbps) speeds, which can support demanding workloads and applications. The switch has 32 ports, allowing for multiple devices to be connected at once. It also offers low latency, high-bandwidth connectivity, and improved scalability. This product is ideal for businesses that need to manage large datasets and require fast and reliable storage solutions. It can help improve efficiency, reduce downtime, and increase productivity. The M9XT-FC1632 is easy to install, manage, and maintain. It offers high availability and redundancy, ensuring that data is always accessible, even in the event of a failure. Overall, the M9XT-FC1632 is a powerful and reliable option for businesses seeking to optimize their storage networks.- Part Code
- M9XT-FC1632
- Description
- MDS 32G FC Port Expansion module, w/ 16 active ports for Base
- Manufacturer
- CISCO
Product specifications
Expand
Product specifications
Protocols
Fibre Channel standards
FC-PH, Revision 4.3 (ANSI INCITS 230-1994)
FC-PH, Amendment 1 (ANSI INCITS 230-1994/AM1-1996)
FC-PH, Amendment 2 (ANSI INCITS 230-1994/AM2-1999)
FC-PH-2, Revision 7.4 (ANSI INCITS 297-1997)
FC-PH-3, Revision 9.4 (ANSI INCITS 303-1998)
FC-PI, Revision 13 (ANSI INCITS 352-2002)
FC-PI-2, Revision 10 (ANSI INCITS 404-2006)
FC-PI-3, Revision 4 (ANSI INCITS 460-2011)
FC-PI-4, Revision 8 (ANSI INCITS 450-2008)
FC-PI-5, Revision 6 (ANSI INCITS 479-2011)
FC-PI-6 (ANSI INCITS 512-2015)
FC-FS, Revision 1.9 (ANSI INCITS 373-2003)
FC-FS-2, Revision 1.01 (ANSI INCITS 424-2007)
FC-FS-2, Amendment 1 (ANSI INCITS 424-2007/AM1-2007)
FC-FS-3, Revision 1.11 (ANSI INCITS 470-2011)
FC-FS-4
FC-LS, Revision 1.62 (ANSI INCITS 433-2007)
FC-LS-2, Revision 2.21 (ANSI INCITS 477-2011)
FC-LS-3, Includes revision 3.53
FC-SW-2, Revision 5.3 (ANSI INCITS 355-2001)
FC-SW-3, Revision 6.6 (ANSI INCITS 384-2004)
FC-SW-4, Revision 7.5 (ANSI INCITS 418-2006)
FC-SW-5, Revision 8.5 (ANSI INCITS 461-2010)
FC-SW-6
FC-GS-3, Revision 7.01 (ANSI INCITS 348-2001)
FC-GS-4, Revision 7.91 (ANSI INCITS 387-2004)
FC-GS-5, Revision 8.51 (ANSI INCITS 427-2007)
FC-GS-6, Revision 9.4 (ANSI INCITS 463-2010)
FC-GS-7, Includes revision 10.8
FCP, Revision 12 (ANSI INCITS 269-1996)
FCP-2, Revision 8 (ANSI INCITS 350-2003)
FCP-3, Revision 4 (ANSI INCITS 416-2006)
FCP-4, Revision 2b (ANSI INCITS 481-2011)
FC-SB-2, Revision 2.1 (ANSI INCITS 349-2001)
FC-SB-3, Revision 1.6 (ANSI INCITS 374-2003)
FC-SB-3, Amendment 1 (ANSI INCITS 374-2003/AM1-2007)
FC-SB-4, Revision 3.0 (ANSI INCITS 466-2011)
FC-SB-5, Revision 2.00 (ANSI INCITS 485-2014)
FC-BB-6, Revision 2.00 (ANSI INCITS 509-2014)
FC-BB-2, Revision 6.0 (ANSI INCITS 372-2003)
FC-BB-3, Revision 6.8 (ANSI INCITS 414-2006)
FC-BB-4, Revision 2.7 (ANSI INCITS 419-2008)
FC-BB-5, Revision 2.0 (ANSI INCITS 462-2010)
FC-VI, Revision 1.84 (ANSI INCITS 357-2002)
FC-SP, Revision 1.8 (ANSI INCITS 426-2007)
FC-SP-2, Revision 2.71 (ANSI INCITS 496-2012)
FAIS, Revision 1.03 (ANSI INCITS 432-2007)
FAIS-2, Revision 2.23 (ANSI INCITS 449-2008)
FC-IFR, Revision 1.06 (ANSI INCITS 475-2011)
FC-FLA, Revision 2.7 (INCITS TR-20-1998)
FC-PLDA, Revision 2.1 (INCITS TR-19-1998)
FC-Tape, Revision 1.17 (INCITS TR-24-1999)
FC-MI, Revision 1.92 (INCITS TR-30-2002)
FC-MI-2, Revision 2.6 (INCITS TR-39-2005)
FC-MI-3, Revision 1.03 (INCITS TR-48-2012)
FC-DA, Revision 3.1 (INCITS TR-36-2004)
FC-DA-2, Revision 1.06 (INCITS TR-49-2012)
FC-MSQS, Revision 3.2 (INCITS TR-46-2011)
Fibre Channel classes of service: Class 2, Class 3, and Class F
Fibre Channel standard port types: E, F, and B
Fibre Channel enhanced port types: SD, ST, and TE
NVMe/FC
In-band management using IP over Fibre Channel (RFC 2625)
IPv6, IPv4, and Address Resolution Protocol (ARP) over Fibre Channel (RFC 4338)
Extensive IETF-standards-based TCP/IP, SNMPv3, and Remote Monitoring (RMON) MIBs
FC-PH, Revision 4.3 (ANSI INCITS 230-1994)
FC-PH, Amendment 1 (ANSI INCITS 230-1994/AM1-1996)
FC-PH, Amendment 2 (ANSI INCITS 230-1994/AM2-1999)
FC-PH-2, Revision 7.4 (ANSI INCITS 297-1997)
FC-PH-3, Revision 9.4 (ANSI INCITS 303-1998)
FC-PI, Revision 13 (ANSI INCITS 352-2002)
FC-PI-2, Revision 10 (ANSI INCITS 404-2006)
FC-PI-3, Revision 4 (ANSI INCITS 460-2011)
FC-PI-4, Revision 8 (ANSI INCITS 450-2008)
FC-PI-5, Revision 6 (ANSI INCITS 479-2011)
FC-PI-6 (ANSI INCITS 512-2015)
FC-FS, Revision 1.9 (ANSI INCITS 373-2003)
FC-FS-2, Revision 1.01 (ANSI INCITS 424-2007)
FC-FS-2, Amendment 1 (ANSI INCITS 424-2007/AM1-2007)
FC-FS-3, Revision 1.11 (ANSI INCITS 470-2011)
FC-FS-4
FC-LS, Revision 1.62 (ANSI INCITS 433-2007)
FC-LS-2, Revision 2.21 (ANSI INCITS 477-2011)
FC-LS-3, Includes revision 3.53
FC-SW-2, Revision 5.3 (ANSI INCITS 355-2001)
FC-SW-3, Revision 6.6 (ANSI INCITS 384-2004)
FC-SW-4, Revision 7.5 (ANSI INCITS 418-2006)
FC-SW-5, Revision 8.5 (ANSI INCITS 461-2010)
FC-SW-6
FC-GS-3, Revision 7.01 (ANSI INCITS 348-2001)
FC-GS-4, Revision 7.91 (ANSI INCITS 387-2004)
FC-GS-5, Revision 8.51 (ANSI INCITS 427-2007)
FC-GS-6, Revision 9.4 (ANSI INCITS 463-2010)
FC-GS-7, Includes revision 10.8
FCP, Revision 12 (ANSI INCITS 269-1996)
FCP-2, Revision 8 (ANSI INCITS 350-2003)
FCP-3, Revision 4 (ANSI INCITS 416-2006)
FCP-4, Revision 2b (ANSI INCITS 481-2011)
FC-SB-2, Revision 2.1 (ANSI INCITS 349-2001)
FC-SB-3, Revision 1.6 (ANSI INCITS 374-2003)
FC-SB-3, Amendment 1 (ANSI INCITS 374-2003/AM1-2007)
FC-SB-4, Revision 3.0 (ANSI INCITS 466-2011)
FC-SB-5, Revision 2.00 (ANSI INCITS 485-2014)
FC-BB-6, Revision 2.00 (ANSI INCITS 509-2014)
FC-BB-2, Revision 6.0 (ANSI INCITS 372-2003)
FC-BB-3, Revision 6.8 (ANSI INCITS 414-2006)
FC-BB-4, Revision 2.7 (ANSI INCITS 419-2008)
FC-BB-5, Revision 2.0 (ANSI INCITS 462-2010)
FC-VI, Revision 1.84 (ANSI INCITS 357-2002)
FC-SP, Revision 1.8 (ANSI INCITS 426-2007)
FC-SP-2, Revision 2.71 (ANSI INCITS 496-2012)
FAIS, Revision 1.03 (ANSI INCITS 432-2007)
FAIS-2, Revision 2.23 (ANSI INCITS 449-2008)
FC-IFR, Revision 1.06 (ANSI INCITS 475-2011)
FC-FLA, Revision 2.7 (INCITS TR-20-1998)
FC-PLDA, Revision 2.1 (INCITS TR-19-1998)
FC-Tape, Revision 1.17 (INCITS TR-24-1999)
FC-MI, Revision 1.92 (INCITS TR-30-2002)
FC-MI-2, Revision 2.6 (INCITS TR-39-2005)
FC-MI-3, Revision 1.03 (INCITS TR-48-2012)
FC-DA, Revision 3.1 (INCITS TR-36-2004)
FC-DA-2, Revision 1.06 (INCITS TR-49-2012)
FC-MSQS, Revision 3.2 (INCITS TR-46-2011)
Fibre Channel classes of service: Class 2, Class 3, and Class F
Fibre Channel standard port types: E, F, and B
Fibre Channel enhanced port types: SD, ST, and TE
NVMe/FC
In-band management using IP over Fibre Channel (RFC 2625)
IPv6, IPv4, and Address Resolution Protocol (ARP) over Fibre Channel (RFC 4338)
Extensive IETF-standards-based TCP/IP, SNMPv3, and Remote Monitoring (RMON) MIBs
Fibre Channel ports
Fixed switch form factor with 16 SFP+ ports base and one 16 SFP+ port expansion slot
Entry-level 8-port preactivated base model with flexibility to turn on any 8 ports
Incremental ports
On the 8-port base model, with the 8-Port On- Demand Activation license to activate up to 16 ports on the base switch
On the 8-port base model, with the 16-port expansion module to activate up to 24 ports
On the 16-port configuration, with the 16-port expansion module to activate up to 32 ports
On the 24-port configuration, with the 8-Port On- Demand Activation license to activate up to 32 ports
Entry-level 8-port preactivated base model with flexibility to turn on any 8 ports
Incremental ports
On the 8-port base model, with the 8-Port On- Demand Activation license to activate up to 16 ports on the base switch
On the 8-port base model, with the 16-port expansion module to activate up to 24 ports
On the 16-port configuration, with the 16-port expansion module to activate up to 32 ports
On the 24-port configuration, with the 8-Port On- Demand Activation license to activate up to 32 ports
Security
VSAN fabric isolation
Intelligent packet inspection @ port level
Hardware zoning by Access Control Lists (ACLs)
FC-SP switch-to-switch authentication
FC-SP host-to-switch authentication
RBAC using RADIUS, TACACS+ or LDAP Authentication, Authorization, and Accounting (AAA) functions
Secure FTP (SFTP)
Secure Shell Version 2 (SSHv2)
Simple Network Management Protocol Version 3 (SNMPv3) implementing Advanced Encryption Standard (AES)
Control-plane security
Cisco TrustSec payload encryption
Secure Boot and Anti-counterfeit technology
Intelligent packet inspection @ port level
Hardware zoning by Access Control Lists (ACLs)
FC-SP switch-to-switch authentication
FC-SP host-to-switch authentication
RBAC using RADIUS, TACACS+ or LDAP Authentication, Authorization, and Accounting (AAA) functions
Secure FTP (SFTP)
Secure Shell Version 2 (SSHv2)
Simple Network Management Protocol Version 3 (SNMPv3) implementing Advanced Encryption Standard (AES)
Control-plane security
Cisco TrustSec payload encryption
Secure Boot and Anti-counterfeit technology
Performance
Port speed: 4/8/16/32-Gbps autosensing with 32 Gbps of dedicated bandwidth per port
Aggregate bandwidth of 1024 Gbps end-to-end full duplex
Buffer credits: Up to 8300 for a group of 16 ports, with a default of 500 buffer credits per port and a maximum of 8270 buffer credits for a single port in the group
Port channel: Up to 16 load-balanced physical links grouped in one port channel
Aggregate bandwidth of 1024 Gbps end-to-end full duplex
Buffer credits: Up to 8300 for a group of 16 ports, with a default of 500 buffer credits per port and a maximum of 8270 buffer credits for a single port in the group
Port channel: Up to 16 load-balanced physical links grouped in one port channel
Diagnostics
Power-on-Self-Test (POST) diagnostics
Online Health Management System (OHMS) diagnostics
Internal loopbacks
SPAN
Fibre Channel traceroute
Fibre Channel ping
Fibre Channel debug
Cisco Fabric Analyzer
Syslog
Port-level statistics
Link Diagnostics (ISL Diagnostics and HBA Diagnostics)
Read Diagnostic Parameter
Online Health Management System (OHMS) diagnostics
Internal loopbacks
SPAN
Fibre Channel traceroute
Fibre Channel ping
Fibre Channel debug
Cisco Fabric Analyzer
Syslog
Port-level statistics
Link Diagnostics (ISL Diagnostics and HBA Diagnostics)
Read Diagnostic Parameter
Serviceability
Configuration file management
Call Home
Port beaconing
Link Cable Beacon
System LEDs
SNMP traps for alerts
Call Home
Port beaconing
Link Cable Beacon
System LEDs
SNMP traps for alerts
Reliability and availability
Cisco In-Service Software Upgrade (ISSU)
Hot-swappable, dual redundant power supplies
Hot-swappable fan tray with switch integrated temperature and power management
Hot-swappable SFP+ optics
Stateful process restart
Any port configuration for port channels
Fabric-based multi pathing
Per-VSAN fabric services
Port tracking
VRRP for management IP interface
Hot-swappable, dual redundant power supplies
Hot-swappable fan tray with switch integrated temperature and power management
Hot-swappable SFP+ optics
Stateful process restart
Any port configuration for port channels
Fabric-based multi pathing
Per-VSAN fabric services
Port tracking
VRRP for management IP interface
Network management
Management access through 2 out-of-band 10/100/1000 Mbps Ethernet ports
mgmt0: 10/100/1000BASE-T port
mgmt1: 10/100/1000BASE-T port
RS-232 serial console port
USB power-on auto-provision port
Access protocols
Command-Line Interface (CLI) using the console and Ethernet port
SNMPv3 using the Ethernet port and in-band IP over Fibre Channel access
Storage Networking Industry Association (SNIA) Storage Management Initiative Specification (SMI-S)
NX-API for restful access via HTTPS
Distributed device alias service
Network security
Per-VSAN Role-Based Access Control (RBAC) using LDAP, RADIUS and TACACS+-based Authentication, Authorization, and Accounting (AAA) functions
SFTP
SSHv2 implementing AES
SNMPv3 implementing AES
Cisco Data Center Network Manager
mgmt0: 10/100/1000BASE-T port
mgmt1: 10/100/1000BASE-T port
RS-232 serial console port
USB power-on auto-provision port
Access protocols
Command-Line Interface (CLI) using the console and Ethernet port
SNMPv3 using the Ethernet port and in-band IP over Fibre Channel access
Storage Networking Industry Association (SNIA) Storage Management Initiative Specification (SMI-S)
NX-API for restful access via HTTPS
Distributed device alias service
Network security
Per-VSAN Role-Based Access Control (RBAC) using LDAP, RADIUS and TACACS+-based Authentication, Authorization, and Accounting (AAA) functions
SFTP
SSHv2 implementing AES
SNMPv3 implementing AES
Cisco Data Center Network Manager
Programming interfaces
Scriptable CLI
Cisco DCNM web services API
NX-API restful interfaces
On-board Python interpreter
Cisco Embedded Event Manager
Cisco NX-OS Software scheduler
Cisco DCNM web services API
NX-API restful interfaces
On-board Python interpreter
Cisco Embedded Event Manager
Cisco NX-OS Software scheduler
Physical dimensions (HxWxD) and weight
1RU (1.72 inches x 17.3 inches x 20.11 inches) excluding Power Supply Unit (PSU) and fan tray handles
9.1 kg with 16 activated ports
9.82 kg with all 32 activated ports
9.1 kg with 16 activated ports
9.82 kg with all 32 activated ports
Power
80 Plus Platinum certified power supplies
Power supply options
650W AC in base model, port-side exhaust variant (up to 2 per switch)
650W AC in base model, port-side intake variant (up to 2 per switch)
Power cord
IEC60320 C14 plug on 650W power supply connecting to a notched C15 socket connector (check Table 6 for power cords specific to regions)
AC input: 100 to 240V AC (10% range)
Frequency: 50 to 60 Hz (nominal)
Typical power consumption
72W for idle base switch with 16 ports activated without SFPs
43W for idle expansion module with 16 ports activated without SFPs
80W for 8 ports activated with 32G SFPs with traffic at 25°C
Airflow
Back to front (toward ports) using port-side exhaust fans
Front to back (inward from ports) using port-side intake fans
50 Cubic Feet per Minute (CFM) through system fan assembly at 25°C
100 CFM maximum
Power supply options
650W AC in base model, port-side exhaust variant (up to 2 per switch)
650W AC in base model, port-side intake variant (up to 2 per switch)
Power cord
IEC60320 C14 plug on 650W power supply connecting to a notched C15 socket connector (check Table 6 for power cords specific to regions)
AC input: 100 to 240V AC (10% range)
Frequency: 50 to 60 Hz (nominal)
Typical power consumption
72W for idle base switch with 16 ports activated without SFPs
43W for idle expansion module with 16 ports activated without SFPs
80W for 8 ports activated with 32G SFPs with traffic at 25°C
Airflow
Back to front (toward ports) using port-side exhaust fans
Front to back (inward from ports) using port-side intake fans
50 Cubic Feet per Minute (CFM) through system fan assembly at 25°C
100 CFM maximum
Temperature range
Temperature, ambient operating:
32 to 104°F (0 to 45°C) with port-side exhaust airflow variant
32 to 131°F (0 to 55°C) with port-side intake airflow variant
Temperature, ambient nonoperating and storage: -40 to 158°F (-40 to 70°C)
Relative humidity, ambient (noncondensing) operating: 10 to 90%
Relative humidity, ambient (noncondensing) nonoperating and storage: 10 to 95%
Altitude, operating: -197 to 6500 ft (-60 to 2000m)
32 to 104°F (0 to 45°C) with port-side exhaust airflow variant
32 to 131°F (0 to 55°C) with port-side intake airflow variant
Temperature, ambient nonoperating and storage: -40 to 158°F (-40 to 70°C)
Relative humidity, ambient (noncondensing) operating: 10 to 90%
Relative humidity, ambient (noncondensing) nonoperating and storage: 10 to 95%
Altitude, operating: -197 to 6500 ft (-60 to 2000m)
Approvals and compliance
Safety compliance
CE Marking
UL 60950
CAN/CSA-C22.2 No. 60950
EN 60950
IEC 60950
TS 001
AS/NZS 3260
IEC60825
EN60825
21 CFR 1040
EMC compliance
FCC Part 15 (CFR 47) Class A
ICES-003 Class A
EN 55022 Class A
CISPR 22 Class A
AS/NZS 3548 Class A
VCCI Class A
EN 55024
EN 50082-1
EN 61000-6-1
EN 61000-3-2
EN 61000-3-3
CE Marking
UL 60950
CAN/CSA-C22.2 No. 60950
EN 60950
IEC 60950
TS 001
AS/NZS 3260
IEC60825
EN60825
21 CFR 1040
EMC compliance
FCC Part 15 (CFR 47) Class A
ICES-003 Class A
EN 55022 Class A
CISPR 22 Class A
AS/NZS 3548 Class A
VCCI Class A
EN 55024
EN 50082-1
EN 61000-6-1
EN 61000-3-2
EN 61000-3-3
Fabric services
Name server
Registered State Change Notification (RSCN)
Login services
Fabric Configuration Server (FCS)
Broadcast
In-order delivery
Registered State Change Notification (RSCN)
Login services
Fabric Configuration Server (FCS)
Broadcast
In-order delivery
Advanced functions
VSAN
IVR
Port channel with multipath load balancing
Flow-based and zone-based QoS
IVR
Port channel with multipath load balancing
Flow-based and zone-based QoS
Supported Cisco optics, media, and transmission distances
For detailed information about all supported transceivers, seeCisco MDS 9000 Family pluggable transceivers documentation
Base modules
Expand
Base modules
Description
Part number
MDS 9132 32G 1 RU FC switch, w/ 8 active FC ports, 2 Fans, 1 PSU, Port Side Exhaust
DS-C9132T-MEK9
MDS 9132 32G 1 RU FC switch, w/ 8 active FC ports, 2 Fans, 1 PSU, Port Side Intake
DS-C9132T-MIK9
MDS 9132T 32G FC switch 8 Port Activation License for Base
M9132T-PL8
Spare modules
Expand
Spare modules
Description
Part number
MDS 9132 32G 1 RU FC switch, w/ 8 active FC ports, 2 Fans, 1 PSU, Port Side Exhaust, spare
DS-C9132T-MEK9=
MDS 9132 32G 1 RU FC switch, w/ 8 active FC ports, 2 Fans, 1 PSU, Port Side Intake, spare
DS-C9132T-MIK9=
MDS 32G FC 16-Port expansion module, w/ 16 active ports, spare
M9XT-FC1632=
MDS 9132T 32G FC switch 8 Port Activation License, spare
M9132T-PL8=
AC PSU Port side Exhaust, spare
DS-CAC-650W-E=
AC PSU Port side Intake, spare
DS-CAC-650W-I=
MDS 9132T FAN tray, port side Exhaust, spare
DS-C32S-FAN-E=
MDS 9132T FAN tray, port side Intake, spare
DS-C32S-FAN-I=
Bundled configurations
Expand
Bundled configurations
Description
Description
Part number
MDS 9132T 32G FC switch, w/ 8 active ports + 8x16G SW Optics, 2 Fans, 1 PSUs, Port Side Exhaust
DS-C9132T-8PMESK9
MDS 9132T 32G FC switch, w/ 8 active ports + 8x16G SW Optics, 2 Fans, 1 PSUs, Port Side Intake
DS-C9132T-8PMISK9
MDS 9132T 32G FC Enterprise switch, w/ 24 active ports + 24x16G SW Optics, 4 Fans, 2 PSUs, Enterprise license, Port Side Exhaust
DS-C9132T-24PESK9
MDS 9132T 32G FC Enterprise switch, w/ 24 active ports + 24x16G SW Optics, 4 Fans, 2 PSUs, Enterprise license, Port Side Intake
DS-C9132T-24PISK9
MDS 9132T 32G FC switch, w/ 8 active ports + 8x32G SW Optics, 2 Fans, 1 PSUs, Port Side Exhaust
DS-C9132T-8PMETK9
MDS 9132T 32G FC switch, w/ 8 active ports + 8x32G SW Optics, 2 Fans, 1 PSUs, Port Side Intake
DS-C9132T-8PMITK9
MDS 9132T 32G FC switch, w/ 24 active ports + 24x32G SW Optics, 4 Fans, 2 PSUs, Port Side Exhaust (Enterprise license not included)
DS-C9132T-24PETK9
MDS 9132T 32G FC switch, w/ 24 active ports + 24x32G SW Optics, 4 Fans, 2 PSUs, Port Side Intake (Enterprise license not included)
DS-C9132T-24PITK9
Power cords
Expand
Power cords
Description
Description
Part number
Power Cord, 250VAC 10A IRAM 2073 Plug, Argentina
CAB-9K10A-AR
Power Cord, 250VAC 10A 3112 Plug, Australia
CAB-9K10A-AU
Power Cord, 250VAC 10A GB1002 Plug, China
CAB-9K10A-CH
Power Cord, 250VAC 10A CEE 7/7 Plug, EU
CAB-9K10A-EU
Power Cord, 250VAC 10A SI16S3 Plug, Israel
CAB-9K10A-ISR
Power Cord, 250VAC 10A CEI 23-16/VII Plug, Italy
CAB-9K10A-IT
Power Cord, 125VAC 13A KSC8305 Plug, Korea
CAB-9K10A-KOR
Power Cord, 250VAC 10A SABS 164/1 Plug, South Africa
CAB-9K10A-SA
Power Cord, 250VAC 10A, Straight C15, MP232 Plug, SWITZ
CAB-9K10A-SW
Power Cord, 125VAC 15A CNS10917-2, Taiwan
CAB-9K10A-TWN
Power Cord, 250VAC 10A BS1363 Plug (13 A fuse), UK
CAB-9K10A-UK
Power Cord, 125VAC 13A NEMA 5-15 Plug, North America
CAB-9K12A-NA
Power Cord, 250VAC 10A, Brazil
CAB-250V-10A-BR
Cabinet Jumper Power Cord, 250 VAC 13A, C14-C15 Connectors
CAB-C15-CBN
Cabinet Jumper Power Cord, 250 VAC 13A, C14-C15 Connectors, China, Republic of Korea
CAB-C15-CBN-CK
Cabinet Jumper Power Cord, 250 VAC 13A, C14-C15 Connectors, EU, Russian Federation, Belarus, Kazakhstan and Australia
CAB-C15-CBN-EURA
Transceivers
Expand
Transceivers
Description
Part number
32G FC Shortwave Optics
DS-SFP-FC32G-SW
32G FC Longwave Optics
DS-SFP-FC32G-LW=
16G FC Shortwave Optics
DS-SFP-FC16G-SW
16G FC Longwave Optics
DS-SFP-FC16G-LW=
8G FC Shortwave Optics
DS-SFP-FC8G-SW=
8G FC Longwave Optics
DS-SFP-FC8G-LW=
System requirements
Expand
System requirements
Item
Requirement
Cisco NX-OS Software for switch
Cisco MDS NX-OS 8.2(1) or later
Cisco Data Center Network Manager
Cisco DCNM 10.4(1) or later
Accessories
Expand
Accessories
Description
Part number
MDS 9132T Accessory Kit for Cisco
DS-9132T-KIT-CSCO
MDS 9132T Accessory Kit for Cisco, spare
DS-9132T-KIT-CSCO=
MDS 9132T Accessory Kit for Dell/EMC
DS-9132T-KIT-EM
MDS 9132T Accessory Kit for HDS
DS-9132T-KIT-HDS
MDS 9132T Accessory Kit for IBM
DS-9132T-KIT-IBM
MDS 9132T Accessory Kit for HPE
DS-9132T-KIT-HP