CISCO Refurbished
- Manufacturer
- CISCO
- Condition
- Refurbished
- Availability
- In Stock
- Price
- US$158.00 Enquire
Description
The 341-0401-01 is a networking product manufactured by Cisco. It is a fan module designed for use in Cisco Catalyst 4500 Series Switches. The fan module helps to provide efficient cooling for the switch components, ensuring smooth operation and increased lifespan.The module features four fans, which are hot-swappable, meaning they can be easily replaced without powering down the entire system. The fans are controlled by the switch and can automatically adjust their speed based on the temperature of the unit. This helps to keep the system cool, even during periods of heavy use.The fan module is easy to install and can be fitted into the switch chassis using the provided instructions. Once installed, the module requires minimal maintenance and can provide reliable cooling for years to come.Overall, the Cisco 341-0401-01 fan module is an essential component for anyone utilizing the Cisco Catalyst 4500 Series Switches. With its efficient cooling capabilities and hot-swappable fans, it helps to ensure the smooth operation and longevity of the entire system.
- Part Code
- PWR-3KW-AC-V2
- Description
- 3KW AC Power Module Version 2
- Weight
- 6kg
- Manufacturer
- CISCO
- End of Hardware Support
- Yes
- End of Sale
- Yes
- End of Life
- Yes
Hardware Available for Cisco ASR 9000 & ASR 9900 Series
Expand
Hardware Available for Cisco ASR 9000 & ASR 9900 Series
ASR-9010-DC-V2
ASR-9010-SYS
ASR-9006-DC-V2
ASR-9006-SYS
ASR-9922-DC
ASR-9922
ASR-9912-DC
ASR-9912
PWR-6KW-AC-V3=
A9K-AC-PEM-V3=
PWR-3KW-AC-V2=
A9K-AC-PEM-V2=
PWR-4.4KW-DC-V3=
A9K-DC-PEM-V3=
PWR-2KW-DC-V2=
ASR-9010-FAN-V2
ASR-9006-FAN-V2
ASR-9922-FAN-V2
ASR-9922-FAN-V3
A9K-9912-FAN
A9K-9904-FAN
ASR-9922-FLTR-CV2
ASR-9922-FLTR-LR
ASR-9900-FLTR-LR
Cisco ASR 9006 and ASR 9010
Expand
Cisco ASR 9006 and ASR 9010
ASR 9010: 23 to 122ºF (-5 to 50ºC)
SR-3580: NEBS Criteria Levels (Level 3)
GR-1089-CORE: NEBS EMC and Safety
GR-63-CORE: NEBS Physical Protection
VZ.TPR.9205: Verizon TEEER
EN300 386: Telecommunications Network Equipment (EMC)
ETSI 300 019 Storage Class 1.1
ETSI 300 019 Transportation Class 2.3
ETSI 300 019 Stationary Use Class 3.1
FCC Class 47CFR15 A
ICES 003 Class A
AS/NZS CISRP22 Class A
CISPR 22 (EN55022) Class A
VCCI Class A
BSMI Class A
IEC/EN 61000-3-12: Power Line Harmonics
IEC/EN 61000-3-11: Voltage Fluctuations and Flicker
EN55022: Information Technology Equipment (Emissions)
EN 50121-4: Railway EMC
IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air)
IEC/EN-61000-4-3: Radiated Immunity (10V/m)
IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal)
IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM)
IEC/EN-61000-4-5: Signal Surge Ports (1kV)
IEC/EN-61000-4-5: Surge DC Port (1kV CM, 1kV DM)
IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)
IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m)
IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations
EN55024: Information Technology Equipment (Immunity)
EN50082-1/EN-61000-6-1: Generic Immunity Standard
EN 50121-4: Railway EMC
UL/CSA/IEC/EN 60950-1
IEC/EN 60825 Laser Safety
ACA TS001
AS/NZS 60950
FDA Code of Federal Regulations Laser Safety
Cisco ASR 9904
Expand
Cisco ASR 9904
Width: 17.57 in. (446.28 mm)
Depth: 25.02 in. (635.51 mm)
Weight:
62 lb (28.2 kg) (V2 PEM AND chassis)
114.05 lb (51.84 kg) (2 RSP, Fan Tray, PEM)
1 fan tray
1 PEM (either DC or AC)
1 fan filter
Feed redundancy
Power-supply redundancy
Route processor redundancy
Software redundancy
21- and 23-in. adapters available
Note: Minimum 17.75-in. opening between posts is needed for proper operation.
Active/active nonblocking operation mode in dual-RSP redundant configuration
Fully redundant in dual-RSP redundant configuration
Built-in service-intelligence and traffic-prioritization capability
Multiple power module types:
3 kW AC power module
2.1 kW DC power module
Note: Mixing of AC and DC modules is not supported
DC: N+1 redundancy
Power module redundancy
A/B Feed redundancy
Fully load-sharing power infrastructure
Worldwide ranging DC (-40 to -72V; 50A nominal, 60A maximum)
23 to 122ºF (-5 to 50ºC) for ASR 9910
SR-3580: NEBS Criteria Levels (Level 3)
GR-1089-CORE: NEBS EMC and Safety
GR-63-CORE: NEBS Physical Protection
VZ.TPR.9205: Verizon TEEER
EN300 386: Telecommunications Network Equipment (EMC)
ETSI 300 019 Storage Class 1.1
ETSI 300 019 Transportation Class 2.3
ETSI 300 019 Stationary Use Class 3.1
FCC Class 47CFR15 A
ICES 003 Class A
AS/NZS CISRP22 Class A
CISPR 22 (EN55022) Class A
VCCI Class A
BSMI Class A
IEC/EN 61000-3-12: Power Line Harmonics
IEC/EN 61000-3-11: Voltage Fluctuations and Flicker
EN55022: Information Technology Equipment (Emissions)
EN 50121-4: Railway EMC
IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air)
IEC/EN-61000-4-3: Radiated Immunity (10V/m)
IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal)
IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM)
IEC/EN-61000-4-5: Signal Surge Ports (1kV)
IEC/EN-61000-4-5: Surge DC Port (1kV CM, 1kV DM)
IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)
IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m)
IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations
EN55024: Information Technology Equipment (Immunity)
EN50082-1/EN-61000-6-1: Generic Immunity Standard
EN 50121-4: Railway EMC
UL/CSA/IEC/EN 60950-1
IEC/EN 60825 Laser Safety
ACA TS001
AS/NZS 60950
FDA Code of Federal Regulations Laser Safety
Cisco ASR 9906 and ASR 9910
Expand
Cisco ASR 9906 and ASR 9910
23 to 122ºF (-5 to 50ºC) for ASR 9910
SR-3580: NEBS Criteria Levels (Level 3)
GR-1089-CORE: NEBS EMC and Safety
GR-63-CORE: NEBS Physical Protection
VZ.TPR.9205: Verizon TEEER
EN300 386: Telecommunications Network Equipment (EMC)
ETSI 300 019 Storage Class 1.1
ETSI 300 019 Transportation Class 2.3
ETSI 300 019 Stationary Use Class 3.1
FCC Class 47CFR15 A
ICES 003 Class A
AS/NZS CISRP22 Class A
CISPR 22 (EN55022) Class A
VCCI Class A
BSMI Class A
IEC/EN 61000-3-12: Power Line Harmonics
IEC/EN 61000-3-11: Voltage Fluctuations and Flicker
EN55022: Information Technology Equipment (Emissions)
EN 50121-4: Railway EMC
IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air)
IEC/EN-61000-4-3: Radiated Immunity (10V/m)
IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal)
IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM)
IEC/EN-61000-4-5: Signal Surge Ports (1kV)
IEC/EN-61000-4-5: Surge DC Port (1kV CM, 1kV DM)
IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)
IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m)
IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations
EN55024: Information Technology Equipment (Immunity)
EN50082-1/EN-61000-6-1: Generic Immunity Standard
EN 50121-4: Railway EMC
UL/CSA/IEC/EN 60950-1
IEC/EN 60825 Laser Safety
ACA TS001
AS/NZS 60950
FDA Code of Federal Regulations Laser Safety
Cisco ASR 9912 and ASR 9922
Expand
Cisco ASR 9912 and ASR 9922
SR-3580: NEBS Criteria Levels (Level 3)
GR-1089-CORE: NEBS EMC and Safety
GR-63-CORE: NEBS Physical Protection
VZ.TPR.9205: Verizon TEEER
EN300 386: Telecommunications Network Equipment (EMC)
ETSI 300 019 Storage Class 1.1
ETSI 300 019 Transportation Class 2.3
ETSI 300 019 Stationary Use Class 3.1
FCC Class 47CFR15 A
ICES 003 Class A
AS/NZS CISRP22 Class A
CISPR 22 (EN55022) Class A
VCCI Class A
BSMI Class A
IEC/EN 61000-3-12: Power Line Harmonics
IEC/EN 61000-3-11: Voltage Fluctuations and Flicker
EN55022: Information Technology Equipment (Emissions)
EN 50121-4: Railway EMC
IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air)
IEC/EN-61000-4-3: Radiated Immunity (10V/m)
IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal)
IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM)
IEC/EN-61000-4-5: Signal Surge Ports (1kV)
IEC/EN-61000-4-5: Surge DC Port (1kV CM, 1kV DM)
IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)
IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m)
IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations
EN55024: Information Technology Equipment (Immunity)
EN50082-1/EN-61000-6-1: Generic Immunity Standard
EN 50121-4: Railway EMC
UL/CSA/IEC/EN 60950-1
IEC/EN 60825 Laser Safety
ACA TS001
AS/NZS 60950
FDA Code of Federal Regulations Laser Safety